A modern, dark-lit data center corridor with rows of glowing server racks, highlighting LG’s data center cooling solutions.

Data Center Solutions

Experience LG’s cooling solutions, engineered for the evolving data center—PUE, WUE, low-GWP refrigerants, and high-power chips. Explore innovative cooling technologies tailored for high efficiency.

About Data Center Solutions

LG delivers comprehensive HVAC solutions for data centers, focusing on LG's most advanced cooling technologies. These solutions cater to everything from edge to hyperscale infrastructures.

Diagram of an LG data center cooling system with Centrifugal and Screw Chillers, CDU, CRAH units, and airflow circulation.

* This is a conceptual image provided for understanding. Actual product images and structure may differ from what is shown.

* CRAH : Computer Room Air Handler

* CDU : Coolant Distribution Unit

Why LG Data Center Solutions

Advanced Cooling System

LG delivers advanced thermal solutions tailored to the evolving demands of today’s data centers—from air cooling to next-gen liquid cooling.

Full-Line Portfolio

LG offers a complete range of products, including chillers, CRAH(FWU), CDUs, and more.

This diverse lineup provides tailored solutions for any data center.

BECON Control Solution

The BECON DC cooling control solution streamlines the system by integrating DTC, room cooling, and the cooling plant into a single, unified operating platform.

Product Lineup

Two types of LG chillers—oil-free centrifugal chiller and air-cooled screw chiller—installed in a clean, indoor environment.

Chiller

LG chillers provide consistent, energy-efficient cooling across a wide capacity range from 200 to 5000 tons. Ideal for data center, our lineup includes oil-free inverter models using R-1233zd refrigerant.

LG CDU unit and exploded cold plate system, illustrating advanced cooling for high-performance chips.

CDU & Cold Plate

LG’s CDU features differentiated technologies such as virtual sensors and Active Load Sharing (ALS), enhancing both system stability and efficiency. Our cold plate offers Direct-to-Chip (DTC) cooling optimized for compute-intensive chips through AI-driven thermal designs.

Exploded view of LG’s CRAH (FWU) unit showing modular components including fan blades, filters, and coils.

CRAH (FWU)

LG’s IE5-grade inverter motor helps to provide precise, energy-efficient control with THD below 5%, while shark-skin fan blades reduce noise and enhance airflow. The modular FWU is pre-assembled at the factory to streamline on-site work and shorten installation time.

Unified Cooling Control Solution for Data Center Excellence

Enhance data center efficiency and reliability through the integration of server cooling and chiller plant systems into a single-vendor solution.

LG BECON Data Center Control

BECON optimizes energy efficiency and operational performance in data centers, supports system stability and scalability, and helps improve operations through maintenance features and data analysis support.

Chiller Plant Manager

The Chiller Plant Manager is an integrated chiller plant management system that provides real-time monitoring and data analytics. By ensuring operational reliability during emergency operations, it reduces energy consumption and improves overall efficiency of plant operations.

FAQS

Q.

What's the Difference Between Immersion Cooling and Direct-to-Chip Cooling?

A.

Immersion Cooling submerges components directly in a specially formulated dielectric coolant, which absorbs and dissipates heat efficiently. In contrast, Direct-to-Chip Cooling is a liquid circulation method that delivers coolant directly to critical components like the rack and processor to dissipate heat effectively.

 

LG utilizes Direct-to-Chip technology to supply coolant directly to the rack and processor, featuring efficient and targeted cooling.

Q.

Can LG’s HVAC systems be customized for different data center needs?

A.

Yes, LG offers customized solutions to meet the unique requirements of various data centers. Our experts provide tailored HVAC solutions—whether for small-scale facilities or large infrastructures.

Q.

What are the key features of LG Chiller Plant Manager for data centers?

A.

To ensure reliable and energy-efficient operation of a data center’s chiller system, the implementation of a centralized control solution is essential. Such a system integrates and manages all critical equipment involved in chilled water flow—including chillers, pumps, cooling towers, valves, and heat exchangers—through a unified platform. This approach minimizes control gaps, coordination errors, and system inefficiencies, while also enabling seamless integration with auxiliary cooling systems, such as economizers or outdoor air cooling. In addition, by collecting and analyzing real-time sensor data—including temperature, pressure, flow rate, and power consumption—the system enables continuous monitoring of overall plant conditions.

Discover More about LG Data Center Solution

Download Resources

Discover a variety of information here, including product catalogues and installation manuals. 

Engineering Support

Experience the resources and support we provide to help your business stay ahead.

HVAC Blog

Read the latest articles, news, and more on our blog.

Two virtual hologram windows which are chatting and contact us float next to the laptop and hands are placed behind them.

Contact Us

Please contact us for more information on the product and we will get in touch with you.

Pay with Installments
Check available installment offers for this product and banks according to below information.
Choose your bank that suits you best!
 
 
Logo tienda 0 +INFO ? Cargando... Se ha añadido un nuevo artículo en tu cesta Ver Cesta Seguir comprando